Performance Requirements Of PolPolyamide Profile Performance Specifications According to GB/T 23615.1-2017yamide Profiles

  • TEDA Thermal Break Strip Price

    The following prices are per meter for each model (FOB Shanghai).

  • Polyamide Profile Performance Specifications According to GB/T 23615.1-2017

    FacebookTweetPinLinkedInEmailPrint Performance Requirements Of PolPolyamide Profile Performance Specifications According to GB/T 23615.1-2017yamide Profiles Performance Requirements Of Polyamide Profiles GB/T 23615.1–2017 NO. […]

  • Project Case: Nanjing Platinum Coast Center

    FacebookTweetPinLinkedInEmailPrint The curtain wall and windows of the Nanjing Platinum Coast Center in China use TEDA polyamide thermal break strips. […]

Performance Requirements Of Polyamide Profiles

GB/T 23615.1–2017

NO.

Item

Unit

GB/T 23615.1-2017

TEDA–Technical specification

1

Density

g/cm3

1.30±0.05

1.30±0.05

2

DSC melting peak temperature

≥255

≥260

3

Testing for tensile cracks

——

No cracks

No cracks

4

Shore hardness

——

80±5

80±5

5

Impact Strength (unnotched in low temperature)

kJ/m2

≥50

≥60

6

Tensile Strength (longitudinal)

MPa

≥90

≥100

7

Elongation at break(longitudinal)

——

≥3%

≥3%

8

Elasticity modulus

MPa

≥4 500

≥5 000

9

Tensile strength
(transverse)

Type I  (Section height﹤20mm)

MPa

≥90

≥100

Type I  (Section height≥20mm)

MPa

≥80

≥90

Non-type I

MPa

≥25

≥30

10

High temperature
tensile strength
(transverse)

Type I  (Section height﹤20mm)

MPa

≥55

≥60

Type I  (Section height≥20mm)

MPa

≥45

≥50

Non-type I

MPa

≥20

≥25

11

Low temperature
tensile strength
(transverse)

Type I  (Section height﹤20mm)

MPa

≥90

≥100

Type I  (Section height≥20mm)

MPa

≥80

≥90

Non-type I

MPa

≥25

≥30

12

Water resistance
tensile strength
(transverse)

Type I  (Section height﹤20mm)

MPa

≥85

≥95

Type I  (Section height≥20mm)

MPa

≥75

≥85

Non-type I

MPa

≥22

≥25

13

Aging resistance
tensile strength
(transverse)

Type I  (Section height﹤20mm)

MPa

≥60

≥65

Type I  (Section height≥20mm)

MPa

≥55

≥60

Non-type I

MPa

≥20

≥25

14

Typical thermal
conductivity

Heat flow meter method

W/(m • K)

0.3

0.3

15

Linear expansion coeffecience typical value

-1 K

2.3×10-5~3.5×10-5

2.3×10-5~3.5×10-5

16

When selecting non-Type I polyamide profiles, engineering design verification should be carried out.

  1. Sample water content lesser than 0.2% by weight.
  2. Norm laboratory condition:(23±2)ºC and (50±10)% relative humidity.
Scroll to Top